Product Center

Product Center

Introduction

Lileisenma-LSA series

  • Brand:

    Lileisenma

Support multi-functional customization

Door to door delivery, local service, engineer on-site guidance, installation, commissioning and teaching

Service telephone

15850887188
Details

introduce

-LSA products are aimed at the power range of industrial generators under the most commonly used voltage in the world.

For other special voltages, please consult lileisenma.

-Meet internationally recognized standards

The 4-pole generator complies with the following main international standards and regulations:

-IEC 60034, NEMA mg 1.32 - 33, ISO 8528 / 3, CSA, UL 1446, UL 1004 (optional according to different voltages, classification society regulations, etc.). can

Integrated into units marked CE.

The design, manufacture and identification of the generator are carried out under the environment of ISO9001 and ISO14001 certification.

3.2 - Electrical Performance

-Excitation system: short circuit current capability

Leroy-Somer provides a variety of excitation system options to meet different customer needs:

-Self excited excitation system: no short-circuit current maintenance capability.

-AreP additional winding: it has short-circuit maintenance capacity of 3 times the rated current for 10 seconds.

-PMG permanent magnet excitation: it has short-circuit maintenance capacity of 3 times the rated current for 10 seconds.

-Radio suppression module:

Generators sold to the European Union are equipped with radio suppression module devices as standard to meet the requirements of en55011, group1 and ClassB. This module is suitable for generators sold outside the European Union

The motor is optional. Technical definition

5.3 - Mechanical Properties

-Form:

4-pole generator can provide single bearing or double bearing connection according to customer requirements, as well as transition joints and drive plates matching with main engines.

-Protection:

IP23 standard protection. It can also provide high-grade protection such as IP44 and IP55 to meet user requirements.

-Balance:

All rotors are dynamically balanced in strict accordance with the requirements of iso1940 and nfc51-112 standards. Double bearing rotor adopts half key for action balance.

-Overspeed:

The maximum overspeed capacity is 2250 rpm. (1.25 times the rated speed of 60Hz).

-Insulation and protection:

The 4-pole matching generator is class H insulation. The protection of standard windings can accept relative humidity up to 95% and can be used in the cabin.

For particularly harsh environments, special coverage protection is required.

Parameter
利莱森玛低压发电机LSA系列
ItemMODEL400V/50Hz/3Ph/1500RPM480V/60Hz/3Ph/1800RPM
1500RPMCont.duty/40℃Standby/27℃Cont.duty/40℃Standby/27℃
WDG   6LeadKWKVAKWKVAKWKVAKWKVA
1LSA 40 VS0J6/4126.4878.8810911.2
2LSA 40 VS1J6/4128108.8111012.511.214
3LSA 40 VS2J6/4121012.511.21412.415.513.617
4LSA 40 S3J6/412121513.216.515.21916.821
5LSA 40 S4J6/4121417.515.62017.62219.624.5
6LSA 40 M5J6/412162017.62220252227.5
7LSA 40 M7J6/41218.423202522.42824.831
8LSA 42.3 VS1J6/41220252227.525.231.527.734.7
9LSA 42.3 VS2J6/41221.62724302733.83037.5
10LSA 42.3 VS3J6/41225.63228.235.2324035.244
11LSA 42.3 S4J6/412283530.838.53543.838.548.1
12LSA 42.3 S5J6/4123240364540504455
13LSA 42.3 M7J6/4123645405045.256.55062.5
14LSA 42.3 M8J6/412405044555062.55568.8
15LSA 42.3 L9J6/412486052.86660756682.5
16LSA44.3 S2J6/4125670627770887897
17LSA44.3 S3J6/412648070888010088110
18LSA44.3 S4J6/41272908010090.411399.2124
19LSA44.3 S5J6/4128010088110100125110138
20LSA44.3 M6J6/412100125110138125156138172
21LSA44.3 M8J6/412108135120150135169149186
22LSA44.3 L10J6/412120150132165150188166207
23LSA44.3 L12J6/412132165146182165206182227
24LSA44.3 VL13J6/412144180160200180225200250
25LSA44.3 VL14J6/412160200176220200250220275
26LSA46.3 S4J6/412184230202253230288253316
27LSA46.3 S5J6/412200250220275250313275344
28LSA46.3 M7J6/412220275242303275344303378
29LSA46.3 M8J6/412240300264330300375330412
30LSA46.3 L10J6/412260325286358325406357447
31LSA46.3 L11J6/412292365320400365456402502
32LSA47.3 S4J6/412328410360450410512465581
33LSA47.3 S5J6/412364455400500456570500625
34LSA47.3 M7J6/412400500456570500625560700
35LSA47.3 M8J6/412440550480600552690600750
36LSA47.3 L9J6/412480600528660600750660825
37LSA47.3 L9C6S/46480600528660600750660825
38LSA47.3 L10J6/41252866056745660825728910
39LSA49.3 M6C6S/465847306488107329158041005
40LSA49.3 M65C6S/466007506648307529408241030
41LSA49.3 M8C6S/4665682075694582010259041130
42LSA49.3 L9C6S/467289108161020912114010041255
43LSA49.3 L10C6S/46800100090411301000125011001375
44LSA50.2 M6C6S/4610001250110013751248156013761720
45LSA50.2 L7C6S/4610801350118814851344168014801850
46LSA50.2 L8C6S/4612001500132016501500187516482060
47LSA50.2 VL10C6S/4613121640144018001600200017602200
48LSA52.3 S5C6S/4614881860163720461786223219642455
49LSA52.3 S6C6S/4616002000176022001920240021122640
50LSA52.3 S7C6S/4617602200193624202112264023232904
51LSA52.3 L9C6S/4618882360207725962266283224803115
52LSA52.3 L12C6S/4620482560220028162600325028603575
53LSA52.3 UL16C6S/4622002750242030252720340029923740
Application

It is widely used in industrial and mining enterprises, communications, troops, ports, highways, railways, hotels, schools, shopping malls and other places. It is an ideal emergency standby power supply equipment.